seCTion ProPerTies and general informaTion
C
32" Coverage
1
3
/
8
"
7
/
8
"
3
5
/
8
"
4
9
/
16
"
1. TheoreticalsectionpropertieshavebeencalculatedperAISI2001“SpecicationfortheDesignofCold-formedSteelStructuralMembers.”IxxandSxxare
effectivesectionpropertiesfordeectionandbending.
2. AllowableloadiscalculatedinaccordancewithAISI2001specicationsconsideringbending,shear,combinedbendingandshear,deection.Allowableload
considerstheworstcaseof3and4equalspanconditions.Allowableloaddoesnotaddresswebcripplingor
fasteners/supportconnectionandpanelweightisnotconsidered.
3. DeectionconsiderationislimitedbyamaximumdeectionratioofL/180ofspan.
4. Allowableloadsdonotincludea1/3stressincreaseinuplift.
ALLOWABLE UNIFORM LOADS PSF
(3 or More Equal Spans)
5’ 6’ 7’ 8’ 9’ 10’ 5’ 6’ 7’ 8’ 9’ 10’
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
32” 60
32” 50
32” 50
26
Ga.
24
22
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
0.91
1.20
1.57
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
Inward
Load
Outward
Load
0.0619 0.0847 0.0619 0.0833 70 52 33 22 16 11 71 53 33 22 16 11
0.0870 0.1217 0.0874 0.1209 102 70 44 29 21 15 103 70 44 29 21 15
0.1163 0.1623 0.1200 0.1683 147 92 58 39 27 20 143 92 58 39 27 20
Slope
Substructure
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
ATTACHMENT DETAIL
FASTENING PATTERN
The minimum recommended slope for V-Line 32 roong
panel is 1:12. Metal Sales recommends that in all roof
applications sealants be used on all sidelaps with a stitch
screw 1'-0" on center
V-Line 32 is designed to be utilized over open structural
framing or a solid substrate. To avoid panel distortion use a
properly aligned and uniform substructure.
V-Line 32 is available in 1 3/8" rib height with a coverage
width of 32".
Minimum factory cut length is 5'-0". Maximum
recommended panel length is 45'-0". Longer panels
require additional consideration in packaging, shipping, and
erection. Please consult Metal Sales for recommendations.
The fastener selection guide should be consulted for
choosing the proper fastener for specic applications.
Quantity and type of fastener must meet necessary loading
and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Acrylic Coated Galvalume
®
, MS Colorfast45
®
, or
various Kynar 500 (PVDF) colors.
Gauges: 24 ga, 26 ga standard and 22 ga optional.
Tape Sealant